Water Quality Testing Equipment Water Hardness Tester
Basic Info.
Model NO. | NYD300 |
Calibrating Method | Standard Hardness Test Blocks |
Rated Voltage | DC9V |
Support Language | English |
Customized | Non-Customized |
Measure Method | Electrode Method |
Calibration | B1\B2 and B3 Calibration Solution |
Hardness Unit | Mmol/L\Mg/L(CaCO3)\Mg/L(Cao)\Mmol/L(Boiler)/M |
Communication Software | Wh-Link |
Usage | School, Research, Mining |
Interface | RS232 |
Software | Wh-Link Communication Software |
Parameter | Mmol/L, Mg/L (CaCO3), Mg/L (Cao), Mmol/L (Boiler) |
Electrode | 601-F |
Product Name | Water Hardness Tester |
Transport Package | 1set |
Specification | ISO, CE |
Trademark | NANBEI |
Origin | Henan, China(Mainland) |
HS Code | 9024102000 |
Production Capacity | 1000set/Sets a Month |
Product Description
Water quality testing equipment water hardness testerPortable meter for measurement of water hardness by electrode measurement method, suited in field and on site.Product Introduction:
Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion). |
Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use. |
Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc. |
Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three units: ºfH(France),ºdH (Germany)and ºeH(UK) from WH-Link communication software. |
Equipped with B1,B2 and B3 calibration solution. |
Equipped with WH-Link communication software, connect testing data of meter to computer. |
Specification:
Water Hardness | Measuring range ResolutionAccuracyTemp. compensationCalibration Solution Calibration Mode | (0 ~ 10)mmol/L; (0 ~ 401)mg/L(Ca);(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);(0 ~ 561)mg/L(CaO); (0 ~ 56)ºdH(German Degree);(0 ~ 20)mmol/L(Boiler); (0 ~ 70)ºeH (England Degree).0.01 and 0.1 water hardness units±5% FS(5 ~ 50)ºC((automatic))B1 Calibration Solution - 2.00×10-2 mmol/LB2 Calibration Solution - 2.00×10-1 mmol/LB3 Calibration Solution - 2.00 mmol/L(B3Calibration Solution also can be used for the soaking solution of electrode)(a)B1/B2 Calibration-using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boilerwater.(b)Calibration-using B2 and B3 Calibration Solution,suitable forgeneral water quality. |
Temperature | Measuring rangeResolutionAccuracy | 0 ~ 60ºC0.1ºC±0.5ºC |
Other Technical Parameter | Data storageContent StorageCommunication ConnectorPowerDimension and weightQuality and safe certificate | 128 groupsserial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.RS232DC9V(160×190×70)mm/750gIISO9001:2000 and CE |
working conditions | Ambient temperatureambient humidity | (5~35)ºC≤85%RH |
Standard kits:
1. Model NYD300 water hardness meter | 1set |
2.Model 601-S water hardness electrode( With two measruing heads and one screw plug ) | 1pc |
3. AA cell (1.5V ) | 2pcs (included) |
4.100mL hardness calibration solution ( B1, B2 and B3 ) | 1btl/each |
5.20mL test cup | 6pcs |
6. Test cup pedestal | 1pc |
7.Carring case | 1pc |
8. Operation manual | 1 set |
Optional accessories:
Accessory Category | Description | Specification |
Water hardness electrode | 601-F water hardness electrode | Suited for measurement of total concentration of calcium ion and magnesium ion, match YD200 meter, BNC+RCA connector |
Water hardness calibration solution | Water hardness calibration solution B1 | 2.00×10-2 mmol/L,500mL/250mL/100mL(bottle) |
Water hardness calibration solution B2 | 2.00×10-1 mmol/L,500mL/250mL/100mL(bottle) | |
Water hardness calibration solution B3 | 2.00 mmol/L,500mL/250mL/100mL(bottle) | |
Accessories | Plasic test cup | Specification:20mL |
Test cup base | Place test cup on the base |
FAQ
1. How can I choose the suitable one?Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.2. Does your price is competitive?Dear customer, we make sure to offer you the best quality with competitive price.3. How can I pay?Dear customer, we accept many payment term, such as T/T, Western Union…4. When I receive it after pay?Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.5. How to deliver?Dear customer, we can send by Express, by Sea and by Air.6. Is will be broken during transport?Dear customer, please do not worry, we do standard export package.7. What should I do if I do not know how to use?Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.8. What should I do if some parts broken?Dear customer, please do not worry, we have 12months warranty except wear parts. You can also buy parts from us after 12months.Company Show:Factory Show:Professional laboratory instrument manufacturer with 11 years of experience.Export experience has been 8 years.Shipping : 5days by courier,door to door serviceCertification:The company has passed various international authoritative certifications such as SGS, CE, ISO.Warranty And After-sale Service♥♥We Supply 1 Year Warranty , And Lifelong Free Technical Guiding And Training♥♥